Trigonox K80 resin with room temperature curing agent
$3.61-19 Others
$3.5820-999 Others
$3.5≥1000Others
Payment Type: | L/C,Western Union,T/T |
Port: | Shanghai Port of China |
$3.61-19 Others
$3.5820-999 Others
$3.5≥1000Others
Payment Type: | L/C,Western Union,T/T |
Port: | Shanghai Port of China |
Model No.: Trigonox K80
Brand: Nouryon
Classification: Chemical Auxiliary Agent
CAS No.: 80-15-9
Other Names: CHP, cumene hydroperoxide
MF: C3h5no)n
EINECS No.: 201-254-7
Type: plastic curing agent
Usage: Plastic Auxiliary Agents
Brand Name: Trigonox
Model Number: Trigonox K-90
Product Name: cumene hydroperoxide
Appearance: Clear Liquid
Product Description: CHP
Certification: Msds
Function: catalyst
Packaging: 20kg/barrel
Packaging Materlal: plastic barrel
Assay: 87.0-90.0%
Density: 1.06 g/cm3
Purity: 100%
Place Of Origin: Jiangsu, China
Model: Trigonox K-90
Place Of Origin: China
Selling Units | : | kilogram |
Package Type | : | plastic barrel |
Picture Example | : |
The file is encrypted. Please fill in the following information to continue accessing it
Trigonox K80 Nouryon CHP cumene hydroperoxide cas 80159
Trigonox K-90 may be used as Curing Agent for Unsaturated Polyester resins.
Without the addition of an Accelerator the polymerization starts only above the activation temperature of 90°C. For the cure at lower temperature Trigonox K-90 must be accelerated by cobalt or vanadium. Together with cobalt accelerators the gel time at room temperature is very long and is therefore particularly suitable for those applications where a long production time is required, for instance in the production of large parts and in filament winding. Sufficiently fast gel and cure times are only obtained above 35°C.
Together with vanadium accelerators Trigonox K- 90 gives a short gel time and a fast cure at room temperature. This can be improved further by adding a special promotor, like pyruvic acid. With such a system it is possible to get a fast cure of UP resins, even at low temperature. Also for resins like vinylester Resin, these combinations are very suitable.
Product description | Cumyl hydroperoxide, 90% in aromatic solvent mixture | |||||||||||||
|
|
|
|
|
|
|
|
| CH3 |
|
| |||
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C |
| O |
| OH |
| ||
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| CH3 |
|
| |||
|
|
|
|
|
|
|
|
|
| |||||
| Molecular weight |
| : 152.2 | |||||||||||
| Active oxygen content Peroxide | : 10.51% | ||||||||||||
| CAS No. |
| : 80-15-9 | |||||||||||
| EINECS/ELINCS No. |
| : 201-254-7 | |||||||||||
| TSCA status |
| : listed on inventory | |||||||||||
Specifications | Appearance |
| : Clear liquid | |||||||||||
| Assay |
| : 87.0-90.0% | |||||||||||
| Color |
| : 200 Pt-Co max. | |||||||||||
| Active Oxygen |
| : 9.14-9.46% | |||||||||||
Characteristics | Density, 20°C |
| : 1.06 g/cm3 | |||||||||||
| Viscosity, 20°C |
| : 10.9 mPa.s | |||||||||||
Storage | Due to the relatively unstable nature of organic peroxides a loss of quality | |||||||||||||
| can be detected over a period of time. To minimize the loss of quality, | |||||||||||||
| AkzoNobel recommends a maximum storage temperature (Ts max.) for | |||||||||||||
| each Organic peroxide product. |
| ||||||||||||
| For Trigonox K-90 | Ts max. = 40°C and | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| Ts min. = -30°C to prevent crystallization | |
| When stored under these recommended storage conditions, Trigonox K-90 | |||||||||||||
| will remain within the AkzoNobel specifications for a period of at least 3 | |||||||||||||
| months after delivery. |
|
| |||||||||||
Thermal stability | Organic peroxides are thermally unstable substances, which may undergo | |||||||||||||
| self-accelerating decomposition. The lowest temperature at which self- | |||||||||||||
| accelerating decomposition of a substance in the original packaging may | |||||||||||||
| occur is the Self-Accelerating Decomposition Temperature (SADT). The | |||||||||||||
| SADT is determined on the basis of the Heat Accumulation Storage Test. | |||||||||||||
| For Trigonox K-90 | SADT : 70°C |
| |||||||||||
| The Heat Accumulation Storage Test is a recognized test method for the determination of the | |||||||||||||
| SADT of organic peroxides (see Recommendations on the Transport of Dangerous Goods, | |||||||||||||
| Manual of Tests and Criteria - United Nations, New York and Geneva). | |||||||||||||
Major decomposition | Acetophenone, 2-Phenylisopropanol, Methane | |||||||||||||
products |
|
|
|
|
|
|
|
|
|
|
|
|
|
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.